11.8.2 Favorites parameter list (default seng)
In the default seng, the most common parameters for the soluon of typical applicaons
are dened as "Favorites":
No. Display code Designaon Default seng Seng range Info
1 P100.00 Output frequency x.x Hz - (Read only) 0x2DDD (P100.00)
2 P103.00 Current actual x.x % - (Read only) 0x6078 (P103.00)
3 P106.00 Motor voltage x VAC - (Read only) 0x2D89 (P106.00)
4 P150.00 Error code - - (Read only) 0x603F (P150.00)
5 P200.00 Control select. Flexible I/O [0] Selecon list 0x2824 (P200.00)
6 P201.01 Freq. setp. src. Analog input 1 [2] Selecon list 0x2860:001 (P201.01)
7 P203.01 Start method Normal [0] Selecon list 0x2838:001 (P203.01)
8 P203.03 Stop method Standard ramp [1] Selecon list 0x2838:003 (P203.03)
9 P208.01 Mains voltage 230 Ve [0] Selecon list 0x2540:001 (P208.01)
10 P210.00 Min. frequency 0.0 Hz 0.0 ... 599.0 Hz 0x2915 (P210.00)
11 P211.00 Max. frequency 50.0 Hz* | 60.0 Hz** 0.0 ... 599.0 Hz 0x2916 (P211.00)
12 P220.00 Accelerat.me 1 5.0 s 0.0 ... 3600.0 s 0x2917 (P220.00)
13 P221.00 Decelerat.me 1 5.0 s 0.0 ... 3600.0 s 0x2918 (P221.00)
14 P300.00 Motor ctrl mode VFC open loop [6] Selecon list 0x2C00 (P300.00)
15 P302.00 V/f charac.shape Linear [0] Selecon list 0x2B00 (P302.00)
16 P303.01 Base voltage 230 V 0 ... 5000 V 0x2B01:001 (P303.01)
17 P303.02 Base frequency 50 Hz* | 60 Hz** 0 ... 1500 Hz 0x2B01:002 (P303.02)
18 P304.00 Limit. rotaon Both rot. direct [1] Selecon list 0x283A (P304.00)
19 P305.00 Switching freq. 0 Selecon list 0x2939 (P305.00)
20 P306.01 Duty selecon Heavy Duty [0] Selecon list 0x2D43:001 (P306.01)
21 P308.01 Max.load.for 60s 150 % 30 ... 200 % 0x2D4B:001 (P308.01)
22 P316.01 Fixed V/f boost 2.5 % 0.0 ... 20.0 % 0x2B12:001 (P316.01)
23 P323.00 Motor current 1.700 A 0.001 ... 500.000 A 0x6075 (P323.00)
24 P324.00 Max current 200.0 % 0.0 ... 3000.0 % 0x6073 (P324.00)
25 P400.01 Enable inverter TRUE [1] Selecon list 0x2631:001 (P400.01)
26 P400.02 Run Digital input 1 [11] Selecon list 0x2631:002 (P400.02)
27 P400.03 Quick stop Not connected [0] Selecon list 0x2631:003 (P400.03)
28 P400.04 Reset fault Digital input 2 [12] Selecon list 0x2631:004 (P400.04)
29 P400.05 DC braking Not connected [0] Selecon list 0x2631:005 (P400.05)
30 P400.06 Start forward Not connected [0] Selecon list 0x2631:006 (P400.06)
31 P400.07 Start reverse Not connected [0] Selecon list 0x2631:007 (P400.07)
32 P400.08 Run forward Not connected [0] Selecon list 0x2631:008 (P400.08)
33 P400.09 Run reverse Not connected [0] Selecon list 0x2631:009 (P400.09)
34 P400.13 Reverse rot.dir. Digital input 3 [13] Selecon list 0x2631:013 (P400.13)
35 P400.18 Setp: Preset b0 Digital input 4 [14] Selecon list 0x2631:018 (P400.18)
36 P400.19 Setp: Preset b1 Digital input 5 [15] Selecon list 0x2631:019 (P400.19)
37 P400.20 Setp: Preset b2 Not connected [0] Selecon list 0x2631:020 (P400.20)
38 P420.01 Relay funcon Rdy for operat. [51] Selecon list 0x2634:001 (P420.01)
39 P420.02 DO1 funcon Release brake [115] Selecon list 0x2634:002 (P420.02)
40 P430.01 AI1 input range 0 ... 10 VDC [0] Selecon list 0x2636:001 (P430.01)
41 P430.02 AI1 freq @ min 0.0 Hz -1000.0 ... 1000.0 Hz 0x2636:002 (P430.02)
42 P430.03 AI1 freq @ max 50.0 Hz* | 60.0 Hz** -1000.0 ... 1000.0 Hz 0x2636:003 (P430.03)
43 P440.01 AO1 outp. range 0 ... 10 VDC [1] Selecon list 0x2639:001 (P440.01)
44 P440.02 AO1 funcon Outp. frequency [1] Selecon list 0x2639:002 (P440.02)
45 P440.03 AO1 min. signal 0 -2147483648 ... 2147483647 0x2639:003 (P440.03)
46 P440.04 AO1 max. signal 1000 -2147483648 ... 2147483647 0x2639:004 (P440.04)
47 P450.01 Freq. preset 1 20.0 Hz 0.0 ... 599.0 Hz 0x2911:001 (P450.01)
48 P450.02 Freq. preset 2 40.0 Hz 0.0 ... 599.0 Hz 0x2911:002 (P450.02)
49 P450.03 Freq. preset 3 50.0 Hz* | 60.0 Hz** 0.0 ... 599.0 Hz 0x2911:003 (P450.03)
50 P450.04 Freq. preset 4 0.0 Hz 0.0 ... 599.0 Hz 0x2911:004 (P450.04)
* Device for 50-Hz mains ** Device for 60-Hz mains Firmware version 05.00.00.00
Addional funcons
Favorites
Favorites parameter list (default seng)