Automac start aer switching on the mains voltage
The automac start can be acvated in 0x2838:002 (P203.02).
Precondions for the automac start:
•
Flexible I/O conguraon is selected: 0x2824 (P200.00) = "Flexible I/O conguraon [0]"
•
For the start command, a digital input has been congured. (In case of keypad or acvated
network control, an automac start is not possible.)
The following diagram demonstrates the funcon:
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
t
t
t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
t
t
0x2838 002:
0x2838 002:
0x2DDD
Mains voltage
= On [1]
= Off [0]
Digital input 1 [11] Run
Constant TRUE [1]
Output signals
Output frequency
Enable inverter
Input signals
Frequency setpoint selection
FunctionTrigger
①
Start at power-up = "O [0]": Aer switching on the mains voltage, a renewed start command is required to start the motor.
②
Start at power-up = "On [1]": Aer switching on the mains voltage, the motor starts automacally if a start command is acve.
Parameter Name / value range / [default seng] Info
0x2838:001
(P203.01)
Start/stop conguraon: Start method
(Start/stop confg: Start method)
•
Seng can only be changed if the inverter is inhibi-
ted.
Behaviour aer start command.
0 Normal Aer start command, the standard ramps are acve.
•
Acceleraon me 1 can be set in 0x2917 (P220.00).
•
Deceleraon me 1 can be set in 0x2918 (P221.00).
1 DC braking Aer start command, the "DC braking" funcon is acve for the me set
in 0x2B84:002 (P704.02).
4DC braking ^ 437
2 Flying restart circuit Aer the start command, the ying restart circuit is acve.
The ying restart funcon makes it possible to restart a coasng motor
during operaon without speed feedback. Synchronicity between the
inverter and motor is coordinated so that the transion to the rotang
motor is eected without jerk at the me of connecon.
4Flying restart circuit ^ 481
3 Start with magnesaon
0x2838:002
(P203.02)
Start/stop conguraon: Start at power-up
(Start/stop confg: Start at powerup)
Starng performance aer switching on the mains voltage.
0 O No automac start aer switching on mains voltage. In addion to the
inverter enable, a renewed start command is always required to start the
motor.
1 On Automac start of the motor aer switching on the mains voltage if the
inverter is enabled and a start command exists.
Basic seng
Starng/stopping performance
Starng performance
154