11.2 Keypad
For the keypad various sengs can be made, which are described in detail in the following
subchapters.
11.2.1 Keypad language selecon
Parameter Name / value range / [default seng] Info
0x2863
(P705.00)
Keypad language selecon
(KP language)
Language selecon for the keypad display.
0 No language selected
1 English
2 German
11.2.2 Keypad setpoint increment
Parameter Name / value range / [default seng] Info
0x2862
(P701.00)
Keypad setpoint increment
(KP setp. incr.)
1 ... [1] ... 100
Adaptaon of the increment for keypad setpoints when a keypad arrow
key is pressed once. The value set serves as a mulplier for the preset
increments.
Preset increments:
0.1 Hz for frequency setpoint 0x2601:001 (P202.01).
0.01 PUnit for process controller setpoint 0x2601:002 (P202.02).
1 % for torque setpoint 0x2601:003 (P202.03).
Notes:
With a seng > 1, the opon of repeatedly changing the setpoint by
pressing the key for a longer me is deacvated.
The seng only has an impact on the keypad setpoints.
Example: with the seng "5", the keypad frequency setpoint is
increased/decreased by 0.5 Hz every me the key is pressed.
11.2.3 Keypad scaling of speed display
Parameter Name / value range / [default seng] Info
0x4002
(P702.00)
Speed display scaling
(Scal.speed fact.)
0.00 ... [0.00] ... 650.00
Factor for the scaling of the speed display in 0x400D (P101.00).
With the seng "0.00", no scaling takes place.
Example: with the "16.50" and the actual frequency = 50 Hz, 0x400D
(P101.00) shows the speed "825 rpm".
0x400D
(P101.00)
Scaled actual value
(Scaled act value)
Read only: x Units
Display of the current speed in applicaon units.
11.2.4 Keypad status display
During operaon, the keypad displays the output frequency of the inverter, or with an acve
PID control it shows the process controller setpoint. Alternavely, an oponal diagnosc
parameter can be displayed during operaon.
Parameter Name / value range / [default seng] Info
0x2864
(P703.00)
Keypad status display
(KP status displ.)
0x00000000 ... [0x00000000] ... 0xFFFFFF00
0 = normal display depending on the operang mode
In case of an acve frequency control, the keypad displays the output
frequency of the inverter.
In case of acve PID control, the keypad displays the current Process
controller setpoint in [P-Unit].
As an alternave, an oponal diagnosc parameter can be set here,
which is to be shown on the keypad during operaon.
Format: 0xiiiiss00 (iiii = hexadecimal index, ss = hexadecimal subindex)
The lowest byte is always 0x00.
The keypad can be used to select the desired diagnoscs parameter
from a list.
Addional funcons
Keypad
Keypad status display
422

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals