Notes:
•
The rmware of the inverter does only support the protecon status.
•
The access protecon is realised by the keypad and engineering tools as "clients" them-
selves based on the current protecon status 0x2040 (P197.00).
More details on how to congure the write access protecon with the respecve client can be
found in the following subchapters:
4Write access protecon in the »EASY Starter« ^ 452
4Write access protecon in the keypad ^ 455
Parameter Name / value range / [default seng] Info
0x203D
(P730.00)
PIN1 access protecon
(PIN1 protecon)
-1 ... [0] ... 9999
PIN denion for write access protecon.
•
1 … 9999 = set/change PIN.
•
0 = delete PIN (deacvate access protecon).
•
When the PIN has been set successfully, the value -1 is shown; other-
wise 0.
•
Seng/changing the PIN via keypad/»EASY Starter« only possible if
no write access protecon is acve.
•
Sengs/changes via »EASY Starter« become eecve immediately;
via keypad they only become eecve when the parameter group has
been exited.
0x203E
(P731.00)
PIN2 access protecon
(PIN2 protecon)
-1 ... [0] ... 9999
0x203F PIN1/PIN2 log-in
-32768 ... [0] ... 32767
Parameter for PIN entry for the purpose of deacvang an acve access
protecon temporarily.
•
1 … 9999 = log-in (deacvate access protecon temporarily).
•
0 = log-out (reacvate access protecon).
•
Aer having logged in successfully, the value 0 is shown; otherwise -1.
•
Aer 10 invalid entries, the log-in funcon is inhibited. In order to
remove the log-in inhibit, the inverter must be switched o and on
again.
0x2040
(P197.00)
Access protecon status
(Protect. status)
•
Read only
Bit-coded display of the acve access protecon aer login by PIN1/
PIN2.
Bit 0 No write access
Bit 1 Only favorites changeable
Addional funcons
Access protecon
Write access protecon
451