Start of sequence mode 0x4040 (P820.00)
The start of sequence mode denes the acon aer the motor is stopped and restarted or
aer the motor has been restarted aer an error occurred.
In the default seng "Restart sequencer [0]", the currently selected sequence is restarted.
The following diagram demonstrates the dierent start of sequence modes:
t
t
t
t
t
t
t
t
0x4040
Segment3
t
Segment2
t
Segment1
t
Start of sequence mode =
Segment 2 End segmentSegment 3
End segmentSegment 3
End segmentSegment 3Segment 2
Segment 3
End segmentSegment 3Segment 2
Segment 2Segment 1Segment 2
Segment 2
Segment 2
Segment 2
Segment 1
Segment 1
Segment 1
Segment 1
Segment 1
End segment
Segment 3Segment 2Segment 1
No action [4]
Start next segment [3]
Continue current segment [2]
Restart current segment [1]
Restart sequencer [0]
Start sequenceDigital input 2 [12]
RunDigital input 1 [11]
Digital input 3 [13] Abort sequence
Input signals
Configured sequence for continuous operation:
FunctionTrigger
Parameter Name / value range / [default seng] Info
0x4025
(P800.00)
Sequencer mode
(Sequencer mode)
From version 02.00
Selecon of the sequencer mode.
0 Disabled
1 Time operaon (from version 03.00) The switch-over to the next step of the sequence is made aer the me
set for the current segment has elapsed.
2 Step operaon (from version 03.00) The switch-over to the next step of the sequence is made via the trigger
assigned in 0x2631:032 (P400.32) to the "Next sequence step" funcon.
3 Time & step operaon (from version 03.00) The switch-over to the next step of the sequence is made via the trigger
assigned in 0x2631:032 (P400.32) to the "Next sequence step" funcon,
but no later than aer the me set for the current segment has elapsed.
0x402F
(P824.00)
End of sequence mode
(End of seq. mode)
From version 03.00
Selecon of the acon aer the sequence has been completed, i. e.,
aer the steps congured for the sequence have been passed through
with the set numbers of cycles.
0 Keep running The setpoint set for the end segment is connuously transmied to the
motor control unl the sequence is aborted.
1 Stop The motor is stopped with the stop method set in 0x2838:003 (P203.03).
The setpoint is connued to be controlled by the sequencer. In order to
return to the normal setpoint control, the sequence must be aborted.
Note!
Aer returning to the normal setpoint control, a start command is
required to restart the motor.
2 Stop and abort The motor is stopped with the stop method set in 0x2838:003 (P203.03).
Aer standsll is reached, it is automacally returned to the normal set-
point control.
Note!
Aer returning to the normal setpoint control, a start command is
required to restart the motor.
3 Abort Return to the normal setpoint control without stopping the motor.
Sequencer
Sequencer basic sengs
521

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals