EasyManuals Logo
Home>Lenze>Inverter>i55AE155F

Lenze i55AE155F User Manual

Lenze i55AE155F
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #645 background imageLoading...
Page #645 background image
21376 0x5380 OEM hardware incompable Keypad display: Incomp. OEM HW
Cause Error type/response Remedy
The control unit (OEM hardware) is not compat-
ible with the power unit (OEM hardware).
Fault
The inverter is inhibited immediately. The
motor becomes torqueless (coasts).
The error can only be reset by mains switch-
ing.
Use compable hardware.
Contact the OEM.
24970 0x618A Internal fan warning Keypad display: Internal fan
Cause Error type/response Remedy
Warning of the internal fan. Warning Check/replace internal fan.
25216 0x6280 Trigger/funcons connected incorrectly Keypad display: P400 cong err
Cause Error type/response Remedy
The assignment direcves have not been
observed.
If the "exible I/O conguraon" is acve as
control source, the "Enable inverter" or
"Run" funcon must be connected to a digi-
tal input in order that the motor can be stop-
ped again any me!
The use of the "Start forward (CW)" and
"Start reverse (CCW)" funcons excludes the
use of the "Run forward (CW)" and "Run
reverse (CCW)" funcons, and vice versa.
Trouble Check and correct the assignment of the trig-
gers for the funcons.
With keypad or network control, the two
"Enable inverter" and "Run" funcons can
also be set to "Constant TRUE [1]" to start
the motor.
Related topics
4Start / stop motor ^ 531
25217 0x6281 User-dened fault 1 Keypad display: User fault 1
Cause Error type/response Remedy
Flexible I/O conguraon: the "Acvate fault 1"
funcon was acvated via the trigger selected
in 0x2631:043 (P400.43).
Fault Eliminate error cause and then reset error.
Related topics
4Triggering a user-dened fault ^ 578
25218 0x6282 User-dened fault 2 Keypad display: User fault 2
Cause Error type/response Remedy
Flexible I/O conguraon: the "Acvate fault 2"
funcon was acvated via the trigger selected
in 0x2631:044 (P400.44).
Fault Eliminate error cause and then reset error.
Related topics
4Triggering a user-dened fault ^ 578
Appendix
Error codes
645

Table of Contents

Other manuals for Lenze i55AE155F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i55AE155F and is the answer not in the manual?

Lenze i55AE155F Specifications

General IconGeneral
BrandLenze
Modeli55AE155F
CategoryInverter
LanguageEnglish

Related product manuals