Crane operation
11.4 Operation of the rated capacity limiter
11 - 46 3 302 819 en Operating manual
GMK3060
13.12.2018
• Select and confirm the symbol (1).
If the rigging mode is permissible
The rigging mode is accepted together with the
display lifting capacity table.
The RCL display shows the Monitoring menu.
The CCS display shows the Start menu.
The crane movements are enabled if no error is
present;
à Checks before operating the crane,
p. 11 - 49.
If a deviation in the outrigger span is detected
A query menu opens.
The display (2) shows the outrigger span corre-
sponding to the RCL code (1).
The display (3) shows the acquired outrigger
span – deviating outrigger spans (4) are red.
• Check the currently rigged outrigger span.
– If an incorrect outrigger span is rigged
• Select and confirm the symbol (5) – the menu closes and the rigging mode
is not adopted.
• Rig the required outrigger span.
– If the necessary outrigger span is rigged
• Select and confirm the symbol (6).
The rigging mode is accepted.
• Have the outrigger span monitoring checked after finishing operations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK3060 and is the answer not in the manual?

Manitowoc GROVE GMK3060 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK3060
CategoryConstruction Equipment
LanguageEnglish

Related product manuals