Alarm Options From the MAIN MENU, press F4, F3, and then F7 to access this screen.
The ALARM OPTIONS screen is used to program and enable Horn and
Light features. Press Tab to select the desired field, or press the desired
function key (F1 - F10). If a field is highlighted, use the UP/DOWN
arrow keys to select the desired choice or value.
Field Definitions
Horn and Lights This field is used to enable the radio’s Horn and Lights Alarm option.
The default is Disabled.
Permanent Horn & Lights This field will be visible only if the Horn and Lights option is enabled. If this
feature is enabled, there will be no repetitive Horn and Lights display
and the radio powers up with alarm armed.
The default is Disabled.
Alarm Rearm Option This field will be visible only if the Horn and Lights option is enabled. If this
option is enabled, Horn and Lights will remain armed even after the
user responds to a call. In this case, the only way to disarm Horn and
Lights is by pressing the H/L button. If this option is disabled, the
alarm is disarmed on receipt of an incoming call.
The default is Disabled.
Ext Alarm Delay (sec) This field will be visible only if the Horn and Lights Option is enabled. This
value in this field represents the time delay before horn and lights are
activated. The valid range is 0 (zero) to 15 seconds.
The default value is 7 seconds.
Horn & Light Duration This field will be visible only if the Horn and Lights Option is enabled. This
field represents the maximum length of time the horn will stay on
before the user responds to a call. Valid values range from 1 to 255. A
value of Infinite is also available.
The default is 4 seconds.
DCG
MOTOROLA Radio Service Software Use UP/DOWN Arrows to Select Choice.
MCS Model:
MAIN:CHANGE/VIEW:CONFIG:ALARM OPTIONS
ALARM OPTIONS
-------------
Horn And Lights............ Enabled
Permanent Horn & Lights...Disabled
Alarm Rearm Option.........Disabled
Ext Alarm Delay (Sec).............7
Horn & Light Duration.............4
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
HELP EXIT

Table of Contents

Other manuals for Motorola MCS 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola MCS 2000 and is the answer not in the manual?

Motorola MCS 2000 Specifications

General IconGeneral
BrandMotorola
ModelMCS 2000
CategoryRadio
LanguageEnglish

Related product manuals