4.
Click Submit.
Resetting Reference Priorities to Factory Defaults
To reset all references in the Reference Priority table to their factory default priorities:
1.
Navigate to the Configure Reference Priorities screen via MANAGEMENT >
OTHER: Reference Priority menu.
2.
In the Actions panel, click the Restore Factory Defaults button.
3.3.1.2 The "Local System" Reference
The Local System reference is a "Self" reference, i.e. VersaSync uses itself as an input ref-
erence for Time, or as a 1PPS reference. The Local System is a unique input reference in
that it can be used as either the Time reference, or the 1PPS reference, but never both.
Note: For VersaSync to operate as a Local System reference, you must
have either a valid external Time reference, or a valid external 1PPS ref-
erence.
3.3 Managing References
CHAPTER 3 • VersaSync User Manual Rev. 7.0
157