-164.0,M (Field not provided in this setup)
(empty field) (Field not provided in this setup)
*47 Checksum data, always begins with *
5.3.2 NMEA RMC Message
NMEA Message Format RMC, (Recommended Minimum) provides fix information, speed
over ground and Magnetic Variance information.
E x a m p l e m e s s a g e :
$GPRMC,123519.00,A,4807.038,N,01131.000,E,,,230394,,,A*6A
Where:
RMC Recommended Minimum Sentence C
123519.00 Fix taken at 12:35:19 UTC
A Status A=active or V=Void.
4807.038,N Latitude 48 deg 07.038' N
01131.000,E Longitude 11 deg 31.000' E
(empty
field)
(Field not provided in this setup)
(empty
field)
(Field not provided in this setup)
230394 Date - 23rd of March 1994
(empty
field)
(Field not provided in this setup)
(empty
field)
(Field not provided in this setup)
A Mode Indicator: A=Autonomous, D=Differential, E=Estimated, F=Float RTK, M=Manual
input, N=No fix, P=Precise, R=Real time kinematic, S=Simulator
*6A Checksum data, always begins with *
5.3.3 NMEA ZDA Message
The Format ZDA Data message provides Date and Time information.
278 VersaSync User Manual
APPENDIX

Table of Contents

Other manuals for Orolia VersaSync

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orolia VersaSync and is the answer not in the manual?

Orolia VersaSync Specifications

General IconGeneral
BrandOrolia
ModelVersaSync
CategoryServer
LanguageEnglish