Format1: Time Transfer (5101)
Format2: Current Status (5040)
Format3: Buffer Box (253)
A configuration of Current Status as Message Format1 and Time Transfer as Format2 res-
ults in broadcasting of the messages Current Status (1Hz), Time Transfer (1Hz), and Buffer
Box (1/6Hz) at their default rates.
Format1: Current Status (5040)
Format2: Time Transfer (5101)
Format3: Buffer Box (253)
5.3.17 EndRun Formats
The following formats provide compatibility with EndRun technology.
5.3.17.1 EndRun Time Format
E x a m p l e m e s s a g e :
T YYYY DDD HH:MM:SS zZZ m<CR><LF>
Where:
T Time Figure of Merit character (TFOM), limited to the range 6 to 9:
9 indicates error >±10 milliseconds, or unsynchronized condition
8 indicates error <±10 milliseconds
7 indicates error <±1 millisecond
6 indicates error <±100 microseconds
YYYY Year
DDD Day of Year (001-366)
HH Hour of the day (00-23)
: Colon Separator
MM Minutes of the hour
SS Seconds (00-59), (00-60 for leap second)
VersaSync User Manual 325
APPENDIX

Table of Contents

Other manuals for Orolia VersaSync

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orolia VersaSync and is the answer not in the manual?

Orolia VersaSync Specifications

General IconGeneral
BrandOrolia
ModelVersaSync
CategoryServer
LanguageEnglish