Protection: IP 65
Vibration:
7.7 g rms, 20 to 1000 Hz (in accordance with MIL-STD 810G, Method 214.6
Category 24: Minimum Integrity and Helicopter Minimum Integrity, see
graphs 514.7E-1 and 514.7E-2)
Shock: 20 g, 11 ms (pulse sawtooth) in accordance with MIL-STD 810G, Method
516.7 Procedure1
1.8 Regulatory Compliance
While the Evaluation Kit (EVK) of this product has not been tested against all standards
below, the production version is planned to be in compliance with the following regulatory
publications:
MIL compliance
Tested in accordance with MIL-STD-810G:
MIL-STD 810G, 506.6
MIL-STD 810G, 509.6
MIL-STD 810G, Method 516.7
MIL-STD 810G, Method 514.7 E1 and E2
MIL-461F Testing (EMI/EMC):
MIL-STD-461F CE102 Conducted Emissions, Power Leads
Note: Frequency Range: 10kHz to 10MHz; Test Limits: Figure CE102-
1
MIL-STD-461F CS101 Conducted Susceptibility, Power Leads
Note: Frequency: 30Hz to 150kHz; Test Levels: Figure CS101- 1
(Curve #2)
MIL-STD-461F RE102 Radiated Emissions, Electric Field
Note: Frequency Range: 10kHz to 18GHz; Test Limits: Figure RE102-
3
MIL-STD-461F CS114 Conducted Susceptibility, Bulk Cable Injection
Note: Frequency Range: 10kHz to 200MHz
FCC compliance
18
CHAPTER 1 • VersaSync User Manual Rev. 7.0
1.8 Regulatory Compliance