Analog modules
6.10 Analog input module SM 331; AI 8 x TC; (6ES7331-7PF11-0AB0)
S7-300 Module data
396 Manual, 06/2017, A5E00105505-AJ
6.10 Analog input module SM 331; AI 8 x TC; (6ES7331-7PF11-0AB0)
Order number
6ES7331-7PF11-0AB0
Properties
8 inputs in 4 channel groups
Programmable measurement type at each channel group
Temperature
Programmable resolution at each channel group (15 bits + sign)
Any measuring range selection per channel group
Programmable diagnostics and diagnostic interrupt
Programmable limit value monitoring for 8 channels
Programmable hardware interrupt when limit is exceeded
High-speed update of measured values at up to 4 channels
Programmable hardware interrupt at end of cycle
Electrically isolated from the CPU
Supports parameter reassignment in RUN
Resolution
The resolution of measured values is independent of the selected integration time.
Diagnostics
For information on diagnostics messages at the "group diagnostics" parameter, refer to
chapter Diagnostic messages of analog input modules (Page 296).
Hardware interrupts
Hardware interrupts for channel groups 0 and 1 can be programmed in
STEP 7
. However,
set a hardware interrupt only for the first channel of a channel group, that is, either at
channel 0, or at channel 2
Terminal assignment
The diagrams below show various wiring options. These examples apply to all channels
(channel 0 to 7).

Table of Contents

Other manuals for Siemens SIMATIC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC and is the answer not in the manual?

Siemens SIMATIC Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC
CategoryControl Unit
LanguageEnglish

Related product manuals