4-8 FI SYSTEM
USING TESTERS
Use the Suzuki multi-circuit tester (09900-25008).
Use well-charged batteries in the tester.
Be sure to set the tester to the correct testing range.
Using the tester
Incorrectly connecting the
+ and
- probes may cause the
inside of the tester to burnout.
If the voltage and current are not known, make measure-
ments using the highest range.
When measuring the resistance with the multi-circuit tester,
will be shown as 10.00 M and “1” flashes in the display.
Check that no voltage is applied before making the measure-
ment. If voltage is applied, the tester may be damaged.
After using the tester, turn the power off.
! 09900-25008: Multi-circuit tester
NOTE:
* When connecting the multi-circuit tester, use a fine needle
pointed probe or install fine copper wires (O.D is below
0.5 mm) to the back side of the lead wire coupler and connect
the probes of tester to them.
* Use a fine copper wire, the outer diameter being below
0.5 mm, to prevent the rubber of the water proof coupler from
damage.
MULTI-CIRCUIT TESTER

Table of Contents

Other manuals for Suzuki DL1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzuki DL1000 and is the answer not in the manual?

Suzuki DL1000 Specifications

General IconGeneral
BrandSuzuki
ModelDL1000
CategoryMotorcycle
LanguageEnglish

Related product manuals