7-6 ELECTRICAL SYSTEM
CHARGING SYSTEM
TROUBLESHOOTING
Generator
Regulator/rectifier
SCR
IC
Ig.switch
Load
Battery
Battery runs down quickly.
Check accessories which use excessive Accessories • Remove accessories.
amounts of electricity.
are installed
No accessories
Check the battery for current Current leaks Short circuit of wire harness
leaks. (
:
7-7) Faulty electrical equipment
No current leaks
Measure the charging voltage
between the battery terminals. Correct Faulty battery
(
:
7-8) Abnormal driving condition
Incorrect
Measure the continuity of
the generator coil. No continuity Faulty generator coil or
(
:
7-8)
disconnected lead wires
Continuity
Continued on next page
•
•
•
•
•