ELECTRICAL SYSTEM 7-23
INSPECTION
LED (LIGHT EMITTING DIODE)
Check that the LED lights immediately after turning the ignition switch on.
If the LED fails in operation, replace the combination meter unit with a new one after checking its wire har-
ness/coupler.
STEPPING MOTOR
Check that the pointer calibrates itself immediately after turning the ignition switch on and stops at starting
point.
If abnormal condition is found, replace the combination meter unit with a new one after checking its wire har-
ness/coupler.
NOTE:
The pointer may not return to the proper position even turning the ignition switch on under low temperature
condition. In that case, you can reset the pointer to the proper position by following the instruction below:
1) With the set switch
A pressed, turn the ignition switch on.
2) Keep pushing the set switch
A for 3 to 5 seconds.
3) Press the set switch
A twice (within 1 second). →
Reset
* Complete the operation within 10 seconds after the ignition switch has been turned on.
Pointer will return to the starting point right after the completion of the operation. In the case of the pointer
not returning to the proper position after doing above, replace the combination meter unit.
A
SET SWITCH
B
MODE SWITCH
Time Ignition switch Set switch
A
OFF
ON
0
•
•
3 sec
5 sec
•
•
•
•
•
10 sec
PUSH
Release
Push
Push → Reset