User's Manual 67. Configuration Parameters Reference
Version 6.8 785 Mediant 500L MSBR
Parameter Description
[ifAlias]
Defines the textual name of the interface. The value is equal
to the ifAlias SNMP MIB object.
The valid range is a string of up to 64 characters.
[SendKeepAliveTrap]
Enables the device to send NAT keep-alive traps to the port
of the SNMP network management station (e.g.,
AudioCodes EMS). This is used for NAT traversal, and
allows SNMP communication with AudioCodes EMS
management platform, located in the WAN, when the device
is located behind NAT. It is needed to keep the NAT pinhole
open for the SNMP messages sent from EMS to the device.
The device sends the trap periodically - every 9/10 of the
time configured by the NATBindingDefaultTimeout
parameter. The trap that is sent is acKeepAlive. For more
information on the SNMP trap, refer to the SNMP Reference
Guide.
ï‚§ [0] = (Default) Disable
ï‚§ [1] = Enable
For configuring the port number, use the KeepAliveTrapPort
parameter.
Note: For this parameter to take effect, a device reset is
required.
EMS: Keep Alive Trap Port
[KeepAliveTrapPort]
Defines the port of the SNMP network management station
to which the device sends keep-alive traps.
The valid range is 0 to 65534. The default is 162.
To enable NAT keep-alive traps, use the
SendKeepAliveTrap parameter.
[PM_EnableThresholdAlarms] Enables the sending of the SNMP trap event,
acPerformanceMonitoringThresholdCrossing which is sent
every time the threshold (high and low) of a Performance
Monitored object (e.g.,
acPMMediaRealmAttributesMediaRealmBytesTxHighThresh
old) is crossed.
ï‚§ [0] = (Default) Disable
ï‚§ [1] = Enable
CLI: sys-oid
[SNMPSysOid]
Defines the base product system OID.
The default is eSNMP_AC_PRODUCT_BASE_OID_D.
Note: For this parameter to take effect, a device reset is
required.
[SNMPTrapEnterpriseOid]
Defines the Trap Enterprise OID.
The default is eSNMP_AC_ENTERPRISE_OID.
The inner shift of the trap in the AcTrap subtree is added to
the end of the OID in this parameter.
Note: For this parameter to take effect, a device reset is
required.
[acUserInputAlarmDescription]
Defines the description of the input alarm.
[acUserInputAlarmSeverity]
Defines the severity of the input alarm.