User's Manual 67. Configuration Parameters Reference
Version 6.8 937 Mediant 500L MSBR
67.10.6.2 TDM Bus and Clock Timing Parameters
The TDM Bus parameters are described in the table below.
Table 67-56: TDM Bus and Clock Timing Parameters
Parameter Description
TDM Bus Parameters
Web/EMS: PCM Law Select
[PCMLawSelect]
Determines the type of pulse-code modulation (PCM)
companding algorithm law in input and output TDM bus.
ï‚§ [1] Alaw
ï‚§ [3] MuLaw
The default value is automatically selected according to the
Protocol Type of the selected trunk. If the Protocol Type is set to
NONE, the default is MuLaw.
Notes:
ï‚§ For this parameter to take effect, a device reset is required.
ï‚§ Typically, BRI is used for most BRI variants.
Web/EMS: Idle PCM Pattern
CLI: idle-pcm-pattern
[IdlePCMPattern]
Defines the PCM Pattern that is applied to the E1/T1 timeslot
(B-channel) when the channel is idle.
The range is 0 to 255. The default is set internally according to
the Law select 1 (0xFF for Mu-Law; 0x55 for A-law).
Note: For this parameter to take effect, a device reset is
required.
Web/EMS: Idle ABCD Pattern
[IdleABCDPattern]
Defines the ABCD (CAS) Pattern that is applied to the CAS
signaling bus when the channel is idle.
The valid range is 0x0 to 0xF. The default is -1 (i.e., default
pattern is 0000).
Notes:
ï‚§ For this parameter to take effect, a device reset is required.
ï‚§
This parameter is applicable only when using PSTN interface
with CAS protocols.
Web/EMS: TDM Bus Clock Source
[TDMBusClockSource]
Defines the clock source to which the device synchronizes.
ï‚§ [1] Internal = (Default) Generate clock from local source.
ï‚§ [4] Network = Recover clock from PSTN line.
Note: For this parameter to take effect, a device reset is
required.
Web/EMS: TDM Bus Local
Reference
[TDMBusLocalReference]
Defines the physical Trunk ID from which the device recovers
(receives) its clock synchronization.
The range is 0 to the maximum number of Trunks. The default is
0.
Note: This parameter is applicable only if the parameter
TDMBusClockSource is set to 4 and the parameter
TDMBusPSTNAutoClockEnable is set to 0.
Web/EMS: TDM Bus Enable
Fallback
[TDMBusEnableFallback]
Defines the automatic fallback of the clock.
ï‚§ [0] Manual (default)
ï‚§ [1] Auto Non-Revertive
ï‚§ [2] Auto Revertive

Table of Contents

Other manuals for AudioCodes Mediant 500L MSBR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 500L MSBR and is the answer not in the manual?

AudioCodes Mediant 500L MSBR Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 500L MSBR
CategoryNetwork Router
LanguageEnglish

Related product manuals