User's Manual 934 Document #: LTRT-10466
Mediant 500L MSBR
67.10.6 PSTN Parameters
This subsection describes the device's PSTN parameters.
67.10.6.1 General Parameters
The general PSTN parameters are described in the table below.
Table 67-55: General PSTN Parameters
Parameter Description
Web: Trunk Name
CLI: name (config-voip >
interface <e1|t1|bri> name
[DigitalPortInfo_x]
Defines an arbitrary name for a trunk (where x denotes the trunk
number for the ini file parameter). This can be used to help you
easily identify the trunk.
The valid value is a string of up to 40 characters. The following
special characters can be used (without the quotes):
ï‚§ " " (space)
ï‚§ "." (period)
ï‚§ "=" (equal sign)
ï‚§ "-" (hyphen)
ï‚§ "_" (underscore)
ï‚§ "#" (pound sign)
By default, the value is undefined.
Web/EMS: Protocol Type
CLI: protocol
[ProtocolType]
Defines the PSTN protocol for all the Trunks. To configure the
protocol type for a specific Trunk, use the ini file parameter
ProtocolType_x:
ï‚§ [0] NONE
ï‚§ [50] BRI EURO ISDN = Euro ISDN over BRI
ï‚§ [51] BRI NI2 ISDN
ï‚§ [52] BRI DMS 100 ISDN
ï‚§ [53] BRI 5ESS 10 ISDN
ï‚§ [54] BRI QSIG = QSIG over BRI
ï‚§ [55] BRI VN6 = VN6 over BRI
ï‚§ [56] BRI NTT = BRI ISDN Japan (Nippon Telegraph)
ï‚§ [57] BRI IUA
Note: The ISDN BRI North American variants (NI-2, DMS-100, and
5ESS) are partially supported by the device. Please contact your
AudioCodes sales representative before implementing this
protocol.
[ProtocolType_x]
Defines the protocol type for a specific trunk ID (where x denotes
the Trunk ID and 0 is the first trunk). For more information, see the
ProtocolType parameter.
[ISDNTimerT310]
Defines the T310 override timer for DMS, Euro ISDN, and ISDN NI-
2 variants. An ISDN timer is started when a Q.931 Call Proceeding
message is received. The timer is stopped when a Q.931 Alerting,
Connect, or Disconnect message is received from the other end. If
no ISDN Alerting, Progress, or Connect message is received within
the duration of T310 timer, the call clears.
The valid value range is 0 to 600 seconds. The default is 0 (i.e.,
use the default timer value according to the protocol's
specifications).

Table of Contents

Other manuals for AudioCodes Mediant 500L MSBR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 500L MSBR and is the answer not in the manual?

AudioCodes Mediant 500L MSBR Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 500L MSBR
CategoryNetwork Router
LanguageEnglish

Related product manuals