User's Manual 92 Document #: LTRT-10466
Mediant 500L MSBR
 To configure SNMP community strings:
1. Open the SNMP Community String page (Configuration tab > System menu >
Management > SNMP > SNMP Community String).
Figure 10-1: SNMP Community String Page
2. Configure SNMP community strings according to the table below.
3. Click Submit, and then save ("burn") your settings to flash memory.
To delete a community string, select the Delete check box corresponding to the community
string that you want to delete, and then click Submit.
Table 10-1: SNMP Community String Parameter Descriptions
Parameter Description
Community String - Read Only
configure system > snmp > ro-
community-string
[SNMPReadOnlyCommunityString_x]
Defines a read-only SNMP community string. Up to five
read-only community strings can be configured.
The valid value is a string of up to 19 characters that can
include only the following:
ï‚§ Upper- and lower-case letters (a to z, and A to Z)
ï‚§ Numbers (0 to 9)
ï‚§ Hyphen (-)
ï‚§ Underline (_)
For example, "Public-comm_string1".
The default is "public".