1. OT one-hole naked crimping connector
Connection
A ground cable grounds a device to protect it from lightning and electromagnetic
interference. A ground cable is connected to a chassis in the following way:
● The OT bare crimp terminal X1 connects to the ground point on the chassis.
● The OT bare crimp terminal X2 connects to the ground bar of the cabinet.
Technical Specications
Table 3-235 Technical specications of chassis ground cable
Dev
ice
Mo
del
Part
Nu
mb
er
Mo
del
Description Con
nec
tor
X1
Connec
tor X2
Le
ngt
h
Fire
Rating
Net
Engi
ne
800
0
F1A
-8H
20Q
250
306
99
- Electronic|Electric Cable,
450V/750V,H07Z-K
UL3386,6mm^2,Yellow/
Green,58A,LSZH
Cable,VDE,UL
OT
Ter
min
al
OT
Termina
l
15
m
IEC
60332-
1,
VM-1
Net
Engi
ne
800
0
F2A
-8K
36H
250
306
98
- Electronic|Electric Cable,
450V/750V,H07Z-K
UL3386,10mm^2,Yellow/
Green,80A,LSZH
Cable,VDE,UL
OT
Ter
min
al
OT
Termina
l
15
m
IEC
60332-
1,VW-
1
250
327
89
- Electronic|Electric Cable,
1100V,Y(FR-LSH),
10mm^2,Yellow/Green,
80A,For India,BIS
OT
Ter
min
al
OT
Termina
l
15
m
IEC603
32-1,IE
C6033
2-3-22
3.5.4 Standard Serial Cable
This section describes the structure and technical
specications of the standard
serial cable.
Introduction
One end of the standard serial cable is a DB9 connector that is connected to the
serial port of a computer, and the other end is an RJ45 connector that is
connected to the standard console port of a router.