EasyManuals Logo
Home>Huawei>Network Router>NetEngine 8000 F

Huawei NetEngine 8000 F User Manual

Huawei NetEngine 8000 F
729 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #599 background imageLoading...
Page #599 background image
NO TE
The protective caps not recommended are made of soft rubber, which are apt to absorb
dust and sundries, and dicult to clean.
4.2.4.5.3 Tools, Equipment, and Materials
Optical connectors should be cleaned using recommended tools, equipment and
materials.
The following provides the recommended tools, equipment and materials:
Optical power meter
400X
ber microscope (A video ber microscope is recommended.)
cassette cleaner shown in Figure 4-236
Cleaning solvent (Isoamylol is preferred, propyl alcohol is the next, and
alcohol or formalin is forbidden.)
Non-woven lens tissue,
ber cleaning tissue, and dustfree cloth (Non-woven
lens tissue is recommended.)
Special compressed air
Special cleaning roll
Dustfree absorbent swab (made of medical cotton or long
ber cotton)
shown in Figure 4-237 and Figure 4-238
Figure 4-236 Cassette cleaner
HUAWEI NetEngine 8000 F
Hardware Guide 4 Hardware Installation and Parts Replacement
Issue 05 (2023-03-31) Copyright © Huawei Technologies Co., Ltd. 588

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei NetEngine 8000 F and is the answer not in the manual?

Huawei NetEngine 8000 F Specifications

General IconGeneral
BrandHuawei
ModelNetEngine 8000 F
CategoryNetwork Router
LanguageEnglish

Related product manuals