• The machine supports AEA and PCA error processing. See Intelligent Printer Data Stream
Reference for details on Sense byte information and error processing.
•
The maximum number of queued asynchronous and synchronous errors is 1 for Twinax and Coax
DSC mode and 7 for Coax LU1 mode and TCP/IP mode.
• The cause of the exception and the Alternate Exception Action (AEA) are the same as specified in
Intelligent Printer Data Stream Reference unless otherwise noted.
TCP/IP Sense Data
Intervention Required Sense Data
Exception ID Meaning Action Code
X'4000..00' Printer not ready 3
X'4001..00' Out of paper 3
X'4002..00' Output bin full 3
X'4004..00' Out of toner 3
X'4031..00' Paper Length Check 3
X'4033..00' Paper Width Check 3
X'40E6..00' Cover open 3
IPDS Exceptions Reported
Command Reject Exceptions
Exception ID Meaning Action Code
X'8001..00' Invalid IPDS command code 01
X'8002..00' Invalid IPDS command
sequence
01
X'8004..00' Data received after ARQ 01
X'80E0..00' Invalid IPDS command length 01
About Exception Reporting, Sense Data, and Recovery
53