Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
174 Configuration Manual, 10/2014, C79000-G8976-C187-22
4.5.7.3
IGMP Configuration
Specifying the aging time
In this menu, you can configure the aging time for IGMP Configuration. When the time
elapses, entries created by IGMP are deleted from the address table if they are not updated
by a new IGMP packet. This applies to all ports; port-specific configuration is not possible in
this case.
Figure 4-68 IGMP Configuration
IGMP Snooping Aging Time [sec]
Here, you enter a time in seconds for the aging time.
IGMP Querier
Enable this option if you want the IE switch to send IGMP queries as well.
Syntax of the Command Line Interface
Table 4- 50 IGMP Configuration - CLI\SWITCH\MCAST\IGMP>
Command
Description
Comment
igmptime [number] Specifies the IGMP aging time in seconds. Without
parameters, this command displays the IGMP aging
time.
Administrator only.
igmpqry [E|D]
Displays/sets IGMP Query Enable
Administrator only.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals