SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
367
Appendix B
B
B.1
MIB variables of a SCALANCE X300/X400
Important variables in the MIB II standard
Below, you will find a list with some of the SNMP variables from the MIB II set for monitoring
device status. MIB II describes all the SNMP variables that are usually supported by all
SNMP-compliant devices.
Variables in the System directory
Table B- 1 Variables in the System directory
Variables
Access rights
Description
sysDescr Read only A string with up to 256 characters is used.
This value contains a vendor-specific identification of
the device.
sysObjectID Read only The address (object identifier) used to access de-
vice-specific SNMP variables is output here:
1.3.6.1.4.1.4196.1.1.5.4
If no private OIDs have been declared, the object
identifier is [0,0]. Here, the value 0 is set as default.
sysUpTime Read only Time since the last reset (for example, after power
up). The value is shown in hundredths of a second.
sysContact Read and write A contact person can be entered here. (Default:
empty string).
Possible value: string with a maximum of 255 charac-
ters.
sysName Read and write A name for the device can be entered here. (Default:
empty string)
Possible value: string with a maximum of 255 charac-
ters.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals