Configuration using Web Based Management and Command Line Interface
4.7 The Router menu (SCALANCE X414-3E)
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
289
Syntax of the Command Line Interface
Table 4- 92 RIPv2 Configuration - CLI\ROUTER\RIP>
Command
Description
Comment
info
Shows the current RIP configuration.
-
rfc1058 <E|D>
Sets RFC1058 (RIPv1) compatibility.
Administrator only.
redistr <E|D> <E|D> <E|D> Enables/disables “redistribute routes”.
Parameter 1
default routes
Parameter 2
static routes
Parameter 3
OSPF routes
Administrator only.
4.7.5
RIPv2 Interfaces
Introduction
The "RIPv2 Interfaces" dialog displays an overview of all IP subnets in which the RIP
protocol is used.
With the "New Entry" button, you can register new subnets for RIP.
Note
Before a subnet can be registered for RIP, it must first be created in the "Router Subnets"
menu.
Figure 4-133 RIPv2 Interfaces
IP Address
IP address of the RIP-compliant subnet (only identifier for this table). All other subnet
parameters such as the subnet mask can be found in the "Router Subnets" dialog.

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals