Configuration using Web Based Management and Command Line Interface
4.2 The System menu
SCALANCE X-300 / X-400
46 Configuration Manual, 10/2014, C79000-G8976-C187-22
4.2.4
System Save & Load via HTTP
System Save & Load HTTP
The WBM allows you to store configuration information in an external file on your client PC
or to load such data from an external file from the PC to IE switches. You can also load new
firmware from a file located on your client PC.
Note
Following a firmware update, delete the cache of the Web browser.
Figure 4-8 System Save & Load via HTTP
Configuration File
Name and directory path of the configuration file you want to load to the IE Switch.
Firmware File
Name and directory path of the file from which you want to load the new firmware.
SSL Private Key File
Name and directory path of the file from which you want to load the private SSL key to the
device.