Page #236 background image
Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
SCALANCE X-300 / X-400
236 Configuration Manual, 10/2014, C79000-G8976-C187-22
4.5.20
Precision Time Protocol (PTP) complying with IEEE 1588
Introduction
The Precision Time Protocol (PTP) complying with IEEE 1588v2 allows the time-of-day
synchronization of devices (time slaves) connected to the ports of a SCALANCE X300.
These devices forward the synchronization frames through the network using the
"Transparent Clock" (TC) mechanism. The connection mechanisms "end-to-end" and "peer-
to-peer" are supported.
Note
PTP is supported only by the following devices of the SCALANCE X300 product line:
•
The device X308-2M.
•
All devices of the X300 EEC product group.
•
All devices of the XR300 product group.
•
All devices of the XR300 EEC product group.
Delay request response mechanism
A device in the network takes over the function of the time master (Best Master Clock, BMC)
that sets the reference time for all other devices. The master sends synchronization

Table of Contents

Other manuals for Siemens SCALANCE X-400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-400 and is the answer not in the manual?

Siemens SCALANCE X-400 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-400
CategorySwitch
LanguageEnglish

Related product manuals