EasyManuals Logo
Home>Siemens>Control Systems>SINUMERIK 804D sl

Siemens SINUMERIK 804D sl Function Manual

Siemens SINUMERIK 804D sl
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Detailed Description
2.4 Protection zones
Axis Monitoring, Protection Zones (A3)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-33
2.4.3 Definition via part program instruction
General
A protection zone definition must contain the following information:
Protection zone type (workpiece- or tool-related)
Orientation of protection zone
Type of limitation in the third dimension
Upper and lower limit of the protection zone in the third dimension
Activation type ("Protection zone immediately active": only possible via system variable)
Contour elements
Definition of protection zones
The following systematics must be maintained in the definition of channel-specific protection
zones:
Definition of the working plane: G17, G18 or G19
Definition beginning
Channel-specific protection zones: CPROTDEF(...)
Machine or NC-specific protection zone: NPROTDEF(...)
Contour description for protection zone
End of definition: EXECUTE(...)
Definition of the working plane
The desired working plane to which the contour description of the protection zone refers
must be selected with G17, G18, G19 before start of the definition. It may not be changed
before the end of the definition. Programming of the applicate is not permitted between start
and end of the definition.

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals