Detailed Description
2.1 Various interface signals and functions (A2)
NC/PLC Interface Signals (Z1)
2-2 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2.1.2 Selection/status signals from MMC to PLC (DB10)
DB10
DBX103.0
MMC alarm is active
Edge evaluation: no Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
At least 1 MMC alarm (alarm numbers 100 000 to 105 999) is active.
Signal state 0 or
edge change 1 → 0
No MMC alarm is active.
DB10
DBX103.5
AT box ready
Edge evaluation: no Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
The AT box for expansion modules is ready.
Signal state 0 or
edge change 1 → 0
The AT box is not ready. An expansion module conforming to the AT specification has either no
functionality or restricted functionality.
References /BH/ Operator Components, Manual; Chapter: "PCU 50 components, spare parts"
DB10
DBX103.6
MMC temperature limit
Edge evaluation: no Signal(s) updated: cyclic
Signal state 1 or
edge change 0 → 1
The ambient conditions of the MMC 101/102 limits are within the permissible tolerance range of
5 to 55 degrees C.
Signal state 0 or
edge change 1 → 0
The MMC temperature limit was either fallen below or exceeded.
The MMC temperature monitoring has responded and disabled the MMC.

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals