Detailed Description
2.3 Configurable gear adaptation
Spindles (S1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-43
The following events have an analog response:
• User ASUB
• Mode change
• Delete distance-to-go
• Axis replacement
• Activate PI user data
• Enable PI service machine data
• Switch over skip block, switch over Dry Run
• Editing in the modes
• Compensation block alarms
• Overstore
• Rapid retraction with G33, G34, G35
• Subroutine level abort, subroutine abort
Response after POWER ON
The active gear step on the machine can be specified by the PLC control after POWER ON
and in the RESET state.
The NCK will then select the appropriate parameter set
and check back the NC/PLC interface signals:
DB31, ... DBX82.0-82.2 (set gear step A to C)
to the PLC.
2.3.4 Gear step change with oscillation mode
What is oscillation?
Oscillation in this context means that the spindle motor rotates alternately in the clockwise
and counterclockwise directions. This oscillation movement makes it easy to engage a new
gear step.