EasyManuals Logo
Home>Siemens>Control Systems>SINUMERIK 804D sl

Siemens SINUMERIK 804D sl Function Manual

Siemens SINUMERIK 804D sl
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
Detailed Description
2.2 Encoder monitoring
Axis Monitoring, Protection Zones (A3)
2-16 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Activation
Actual velocity monitoring is activated as soon as the active measuring system:
DB31, ... DBX1.5 / 1.6 (position measuring system 1 / 2)
supplies valid actual values (encoder limit frequency is not exceeded).
Effectivity
The actual velocity monitoring only operates with active position control and the following
axis types:
Linear axes
Rotary axes
Open loop controlled and position controlled spindles
Effect
Upon exceeding of the threshold, the following occurs:
Alarm: "25030 Axis <
Axis identifier
> Actual velocity alarm limit"
The affected axis is stopped via the configured braking ramp in follow-up mode:
MD36610 $MA_AX_EMERGENCY_STOP_TIME
(Time for braking ramp when an error occurs)
If the axis/spindle is involved in interpolation with other axes/spindles, these are brought
to a standstill with rapid stop (set velocity = 0).
2.2 2.2 Encoder monitoring
2.2.1 Encoder limit frequency monitoring
Function
Monitoring of the parameterized encoder limit frequency:
MD36300 $MA_ENC_FREQ_LIMIT (encoder limit frequency)

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals