Feeds (V1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
3-1
Supplementary Conditions
3
3.1 3.1 General constraints
Several feeds in one block
The "Multiple feeds in one block" function is only available in conjunction with the
"Synchronous actions" function.
References:
/FBSY/ Description of Functions Synchronized Actions
3.2 3.2 Supplementary conditions for feedrate programming
Unit of measurement
The applicable unit of measurement for feedrates is based on the value entered in machine
data:
MD12240 SCALING_SYSTEM_IS_METRIC
(standard control system metric/imperial)
and the type of axis entered in machine data:
MD30300 IS_ROT_AX
(rotary or linear axis).
Standard setting for feedrate type
G94 is displayed on the screen as the standard setting.
The initial setting (standard programming setting) for the feedrate type is only displayed
when the part program starts up.
The initial setting is set in machine data:
MD20150 GCODE_RESET_VALUES (initial setting for G groups).

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals