2.10.4 How many environments and which ones are saved?
$P_TOOLENVN
This system variable returns the number of available data sets for describing tool
environments. (Data sets defined by TOOLENV and not yet deleted).
The range of values is 0 to MD18116 $MN_MM_NUM_TOOL_ENV.
This system variable can be accessed even if no tool environments are possible
(MD18116 = 0). In this case, the return value is 0.
Syntax:
_N = $P_TOOLENVN
Data type:
_N INT
Number of defined TOOLENV
$P_TOOLENV
This system variable returns the number of the nth data set for describing a tool
environment.
The assignment of numbers to data sets is not fixed, but can be changed as a result of
deleting or creating data sets. The data sets are numbered internally. The range is from
1 to $P_TOOLENVN.
Syntax:
_NAME = $P_TOOLENV[i]
Data type:
_NAME STRING
Name of the data set with number i
i INT
Number of the data set.
If an index, which does not refer to a defined data set, is passed, alarm 17020 (illegal array
index1) is output.

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals