Detailed Description
2.6 Block search Type 5 SERUPRO
Mode Group, Channel, Program Operation, Reset Response (K1)
2-76 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2.6.8.8 REPOS offset in the interface
REPOS offset provided/valid
When the SERUPRO operation is finished, the user can use the OPI to read off the REPOS
offset applied via the following REPOS process.
An axis-VDI-interface bit "REPOS offset" is provided. The axis-VDI-interface bit "REPOS
offset" corresponds to DB31.DBX70.BIT0.
Value 0 No REPOS offset has to be applied to this axis
Value 1 A REPOS offset has to be applied to this axis.
Scope: The axis-VDI-interface bit "REPOS offset" is provided when the SERUPRO operation
is finished. The "REPOS offset" is invalid when a SERUPRO ASUB starts or continues. The
axis can be moved in JOG mode with a mode change between the SERUPRO end and start
and the "REPOS offset" bit is continuously updated (i.e., the user traverses the REPOS
offset by hand and the bit changes to 0). In the scope, the axis can also be traversed using
FC18, with the "REPOS offset" continuously being updated.
The scope of "REPOS offset" is displayed with the axis-VDI-interface bit "REPOS offset
valid" DB31.DBX70.BIT1.
DB31.DBX70.BIT1
Value 0 DB31.DBX70.BIT0 has not been validly calculated
Value 1 DB31.DBX70.BIT0 has been validly calculated
2.6.8.9 Making the initial settings more flexible
Initial setting/initial SERUPRO setting
Machine data MD20112 $MC_START_MODE_MASK defines the initial setting of the control
for part program start with respect to the G codes (especially the current plane and settable
zero offset), tool length compensation, transformation, and axis couplings. The special option
exists for the SERUPRO operation of using
MD22620 $MC_ENABLE_START_MODE_MASK_PRT
to select an initial setting that differs from the normal part program start. The new setting
must then be stored in
MD22620 $MC_START_MODE_MASK_PRT.
The meaning of the bits of MD22620 is identical to those of:
MD20112 $MC_START_MODE_MASK.

Table of Contents

Other manuals for Siemens SINUMERIK 804D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 804D sl and is the answer not in the manual?

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 804D sl
CategoryControl Systems
LanguageEnglish

Related product manuals