264
Effect Timeline
Operations (Menu)
Recalling an Effect Timeline
• The first keyframe is executed when an effect timeline
is recalled. You can also configure a setting such that
the first keyframe is not executed.
For details about settings, see “Setting the operation of
the first keyframe when a register is recalled”
(page 416).
• You can configure a setting such
that the state at that
point in time is inserted automatically as the first
keyframe when an empty effect timeline register is
recalled.
For details about settings, see “Inserting the first
keyframe automatically when an empty
register is
recalled” (page 415).
• You can configure a setting such that when anot
her
effect timeline register is recalled while editing an
effect timeline, the edited effect timeline is saved
automatically (auto save function).
For details about settings, see “Saving an effect
timeline automatically” (page 415).
• You can configure a setting such
that effect timeline
edit mode ends and operation switches to effect
timeline recall/store mode when a register is recalled in
edit mode.
For details about settings, see “Exiting edit mode
automatically when a register
is recalled during
editing” (page 416).
1
Display the [Effect Timeline Recall/Store] taskbar.
The effect timeline switche
s to recall/store mode.
2
Press the [Recall/Store] button.
The [Recall/Store Register] window appears.
In the [Effect Timeline Edit] taskbar, press
the
[Recall/Store] button to display the [Recall/Store
Register] window.
3
Set the button for the target region to the on state.
You can select multiple regions.
For details about the display in the
region display
section, see “Region display section” (page 265).
Select a tab to change the region to display.
[ME] tab:
Switcher bank regions
[User] tab: U
ser regions
[DME] tab: DME
regions
[External Device] tab:
External device regions
The first selected region becomes the re
ference
region.
To select all regions configured beforehand
Set the [All Regions] button to the on state.
For details about setting t
he regions selected
simultaneously, see “Setting Regions Selected
Simultaneously” (page 397).
To select DME local or DME global for the target
region to
edit
To select DME local, set the [DME Local] button to
t
he on state.
To select DME global, set the [DME Global] button
to
the on state.
• The region selection is common for effect timelines
and snapshots.
• DME local/DME global selection is enabled only
wh
en editing an effect timeline. When recalling,
saving, or executing an effect timeline, both DME
local and DME global become the target.
• The DME local/DME global selections are
common
for all DME regions.
• The DME local/DME global selections are linked
to the
[LOCAL] button/[GLB] button in the device
control block.
4
Press the [Recall] button.
5
Enter a register number in the numeric keypad area.
For details about selecting a register, see “Selecting
a register” (page 265).
To add a temporary attribute
Set [Effect Diss] in the numeric keypa
d area to the on
state.
6
Press [Enter].
The specified register is recalled.
To undo a register recall
To undo a recall immediately
after recalling a register,
press the [Undo] button.
To set the duration for an effect dissolve
temporary attribute
You can set the duration for an effect dissolve temporary
at
tribute for each region.
Select the target region to set, press the [Temp Diss
Du
ration] button, and enter a duration (number of frames)
for the effect dissolve in the numeric keypad area.
Notes
Note
Notes