G-5
ME8200, ME9000, WSM
G GENERAL
• After installing wiring, check protection of terminals and clamped
condition of wiring, only connect battery.
W1011735
[2] BATTERY
• Take care not to confuse positive and negative terminals.
• When removing battery cord, disconnect negative wire first.
When installing battery cord, check for polarity and connect
positive wire first.
• Do not install any battery with capacity other than is specified
(Ah).
• After connecting cord to battery terminals, apply grease to them
and securely install terminal covers on them.
• Do not allow dirt and dust to collect on battery.
CAUTION
• Take care not to let battery liquid spill on your skin and
clothes. If contaminated, wash it off with water immediately.
• Before recharging the battery, remove it from the machine.
• Before recharging, remove cell caps.
• Do recharging in a well-ventilated place where there is no
open flame nearby, as hydrogen gas and oxygen are formed.
W1011816
[3] FUSE
• Use fuses with specified capacity.
Neither too large or small capacity fuse is acceptable.
• Never use steel or copper wire in place of fuse.
• Do not install working light, radio set, etc. on machine which is not
provided with reserve power supply.
• Do not install accessories if fuse capacity of reserve power
supply is exceeded.
W1012092
(1) Cover
• Securely Install Cover
(1) Fuse (2) Slow Blow Fuse
KiSC issued 03, 2007 A