Printer Configuration Menus
DELIMITER CHAR
Description: This menu item is used to separate command parameters (command
delimiter). The default prefix is the comma (,). The printer looks for this character to
separate parts of ZPL/ZPL II commands. Set the delimiter character to match what is used
in your label formats.
The delimiter command prefix is an ASCII (two-digit hexadecimal value shown in
parenthesis) used as a parameter place marker in ZPL/ZPL II control instructions.
Important • You cannot use the same hex value for the format command prefix, control character,
and delimiter characters. The printer must see different characters to work properly. If you are
setting the value through the interface, the printer will skip any value that is already in use.
Acceptable values: 00 to FF hexadecimal
Related ZPL command(s): ^CD or ~CD
SGD command used: zpl.delimiter
Print Server web page: ViewandModifyPrinterSettings>ZPLControl
LANGUAGE
—
LANGUAGE
—
COMMAND LANGUAGE
—
COMMAND CHAR
—
CONTROL CHAR
—
DELIMITER CHAR
—
ZPL MODE
—
VIRTUAL DEVICE