Confidential
2-56
Error Code E3
Wireless LAN MAC address acquisition error
Error Code E6
Main PCB ASSY EEPROM write error
Error Code EC
LCD disconnection detected.
MACHINE ERROR E3
LCD
Step Cause Solution
1 Wireless LAN PCB ASSY
connection failure
Reconnect the wireless LAN PCB ASSY.
2 Wireless LAN PCB ASSY
defective
Replace the wireless LAN PCB ASSY.
3 Main PCB defective Replace the main PCB ASSY.
MACHINE ERROR E6
LCD
Step Cause Solution
1 Main PCB defective Replace the main PCB ASSY.
MACHINE ERROR EC
LCD
Step Cause Solution
1 LCD flat cable connection failure Reconnect the LCD flat cable.
2 LCD PCB defective Replace the control panel ASSY.