Page #223 background image
Routing Virtual Router Redundancy Protocol (VRRP)
Digi Connect IT® 16/48 User Guide
223
5. Click Enable.
6. For Interface, select Interface: ETH2.
7. For Router ID, leave at the default setting of 50.
8. For Priority, leave at the default setting of 100.
9. Click to expand Virtual IP addresses.
10. Click to add a virtual IP address.
11. For Virtual IP, type 192.168.3.3.
Task 2: Configure VRRP+ on device one
1. Click to expand VRRP+.
2. Click Enable.
3. Click to expand Monitor interfaces.
4. Click to add an interface for monitoring.
5. Select Interface: WWAN.
6. For Priority modifier, type 30.
Task 3: Configure the IP address for the VRRP interface, ETH2, on device one
1. Click Network > Interfaces > ETH2 > IPv4
2. For Address, type 192.168.3.1/24.