Central management Log into Digi Remote Manager
Digi Connect IT® 16/48 User Guide
644
(config)> show monitoring devicehealth tuning
all
cellular
rx
bytes
enable true
tx
bytes
enable true
eth
rx
bytes
enable true
tx
bytes
enable true
serial
rx
bytes
enable true
tx
bytes
enable true
cellular
1
rx
bytes
enable true
packets
enable true
...
(config)>
To disable a tuning parameter, set its value to false. For example, to turn off all reporting for
the serial port:
(config)> monitoring devicehealth tuning all serial rx bytes enabled false
(config)> monitoring devicehealth tuning all serial tx bytes enabled false
(config)>
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Log into Digi Remote Manager
To start Digi Remote Manager