Diagnostics Configure options for the event and system logs
Digi Connect IT® 16/48 User Guide
668
n To disable status event messages:
(config system log remote 0)> status false
(config system log remote 0)>
n To disable informational event messages:
(config system log remote 0)> error false
(config system log remote 0)>
4. Set the port number to use for the syslog server:
(config system log remote 0)> port value
(config system log remote 0)>
where value is any integer between 1 and 65535. The default is 514.
5. Set the IP protocol to use for communication with the syslog server:
(config system log remote 0)> protocol value
(config system log remote 0)>
where value is either tcp or udp. The default is udp.
6. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
7. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Configure options for the event and system logs
The default configuration for event and system logging is:
n The heartbeat interval, which determines the amount of time to wait before sending a
heartbeat event if no other events have been sent, is set to 30 minutes.
n All event categories are enabled.
To change or disable the heartbeat interval, or to disable event categories, and to perform other log
configuration:
WebUI

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi Connect IT 16 and is the answer not in the manual?

Digi Connect IT 16 Specifications

General IconGeneral
BrandDigi
ModelConnect IT 16
CategoryServer
LanguageEnglish

Related product manuals