User authentication User authentication methods
Digi Connect IT® 16/48 User Guide
495
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Use the show auth method command to determine the index number of the authentication
method to be deleted:
(config)> show auth method
0 local
1 radius
2 tacacs+
(config)>
4. Delete the appropriate authentication method:
(config)> del auth method n
Where n is index number of the authentication method to be deleted. For example, to delete
the TACACS+ authentication method as displayed by the example show command, above:
(config)> del auth method 2
5. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
6. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Rearrange the position of authentication methods
WebUI
Authentication methods are reordered by changing the method type in the Method drop-down for
each authentication method to match the appropriate order.
For example, the following configuration has Local users as the first method, and RADIUS as the
second.
To reorder these so that RADIUSis first and Local users is second: