Services Modbus gateway
Digi Connect IT® 16/48 User Guide
410
This will configure the gateway to deliver all messages that have the Modbus server
address address of 20 to the device with address 10.
i. Repeat the above instructions for additional clients.
6. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
7. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.
Show Modbus gateway status and statistics
You can view status and statistics about location information from either the WebUI or the command
line.
WebUI
1. Log into the Connect IT 16/48 WebUI as a user with Admin access.
2. On the menu, select Status > Modbus Gateway.
The Modbus Gateway page appears.
Statistics related to the Modbus gateway server are displayed. If the message Server
connections not available is displayed, this indicates that there are no connected clients.
n To view information about Modbus gateway clients, click Clients.
n To view statistics that are common to both the clients and server, click Common
Statistics.
n To view configuration details about the gateway, click the ï‚­ (configuration) icon in the
upper right of the gateway's status pane.
Command line
1. Log into the Connect IT 16/48 command line as a user with Admin access.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. Use the show modbus-gateway command at the system prompt:
> show modbus-gateway
Server Connection IP Address Port Uptime
----------------- ----------- ----- ------
modbus_socket 10.45.1.139 49570 6
modbus_socket 10.45.1.139 49568 13
Client Uptime
-------------------- ------
modbus_socket_41 0