EasyManuals Logo
Home>Digi>Server>Connect IT 16

Digi Connect IT 16 User Manual

Digi Connect IT 16
756 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #399 background imageLoading...
Page #399 background image
Services Modbus gateway
Digi Connect IT® 16/48 User Guide
399
n If Socket is selected for Connection type:
a. For IP Protocol, select TCP or UDP. The default is TCP.
b. For Port, enter or select an appropriate port. The default is port 502.
n If Serial is selected for Connection type:
a. For Serial port, select the appropriate serial port on the Connect IT 16/48 device.
5. For Packet mode, select RTUor RAW (if Connection type is set to Socket) or ASCII (if
Connection typeis set to Serial) for the type of packet that will be used by this connection.
The default is RTU.
6. For Packet idle gap, type the maximum allowable time between bytes in a packet.
Allowed values are between 10 milliseconds and one second, and take the format number
{ms|s}.
For example, to set Packet idle gap to 20 milliseconds, enter 20ms.
7. If Connection type is set to Socket, for Inactivity timeout, type the amount of time to wait
before disconnecting the socket when it has become inactive.
Allowed values are any number of minutes or seconds up to a maximum of 15 minutes, and
take the format number{m|s}.
For example, to set Inactivity timeout to ten minutes, enter 10m or 600s.
8. (Optional) If Connection type is set to Serial, click Half duplex to enable half duplex (two
wire) mode.
9. (Optional) If Connection type is set to Socket, click to expand Access control list:
n To limit access to specified IPv4 addresses and networks:
a. Click IPv4 Addresses.
b. For Add Address, click .
c. For Address, enter the IPv4 address or network that can access the device's web
administration service. Allowed values are:
l A single IP address or host name.
l A network designation in CIDR notation, for example, 192.168.1.0/24.
l any: No limit to IPv4 addresses that can access the web administration service.
d. Click again to list additional IP addresses or networks.
n To limit access to specified IPv6 addresses and networks:
a. Click IPv6 Addresses.
b. For Add Address, click .
c. For Address, enter the IPv6 address or network that can access the device's web
administration service. Allowed values are:
l A single IP address or host name.
l A network designation in CIDR notation, for example, 2001:db8::/48.
l any: No limit to IPv6 addresses that can access the web administration service.
d. Click again to list additional IP addresses or networks.
n To limit access to hosts connected through a specified interface on the Connect IT
16/48 device:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi Connect IT 16 and is the answer not in the manual?

Digi Connect IT 16 Specifications

General IconGeneral
BrandDigi
ModelConnect IT 16
CategoryServer
LanguageEnglish

Related product manuals