Interfaces Wide Area Networks (WANs)
Digi Connect IT® 16/48 User Guide
73
d. Delete the existing test targets:
Click the menu icon (...) next to each target and select Delete.
e. For Add Test Target, click .
f. For Test type, select Ping test.
g. For Ping host, type 43.66.93.111.
h. For Ping payload size, type 256.
4. Repeat the above step for WWAN to enable SureLink on that interface.
5. Click Apply to save the configuration and apply the change.
Command line
1. Log into the Connect IT 16/48 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Configure SureLink on ETH1:
a. Set the interval to ten seconds:
(config)> network interface eth1 ipv4 surelink interval 10s
(config)>
b. Delete the existing test targets:
(config network interface eth1> del ipv4 surelink target 0
(config network interface eth1> del ipv4 surelink target 1
(config network interface eth1)>
c. Add a test target: