EasyManuals Logo
Home>Emerson>Controller>Unidrive M702

Emerson Unidrive M702 User Manual

Emerson Unidrive M702
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #187 background imageLoading...
Page #187 background image
Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running
the motor
Optimization
NV Media Card
Operation
Onboard
PLC
Advanced
parameters
Technical
data
Diagnostics
UL listing
information
Unidrive M702 User Guide 187
Issue Number: 3
Figure 11-23 Menu 9 logic diagram: Scope function
09.062
x(-1)
Scope
Trigger Invert
09.059
09.061
09.060
OR
+
_
Scope
Trigger
Scope Trigger
Source
Scope Trigger
Threshold
09.063 Scope Mode
09.067 Scope Sample Time
09.068
Scope Trigger Delay
09.069 Time Period
09.055
09.057
09.056
09.064
09.058
09.065
Scope Data
Not Ready
09.066
Scope Saving
Data
Scope Trace 1
Source
Scope Trace 2
Source
Scope Trace 3
Source
Scope Trace 4
Source
Scope Arm
mm.ppp
mm.ppp
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
The parameters are all shown in their default settings

Table of Contents

Other manuals for Emerson Unidrive M702

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Unidrive M702 and is the answer not in the manual?

Emerson Unidrive M702 Specifications

General IconGeneral
BrandEmerson
ModelUnidrive M702
CategoryController
LanguageEnglish

Related product manuals