12.1.2 Power dissipation
Table 12-4 Losses @ 40°C (104°F) ambient
Model
Normal Duty Heavy Duty
Nominal
rating
Drive losses (w) taking into account any
current derating for the given conditions
Nominal
rating
Drive losses (w) taking into account any
current derating for the given conditions
kW hp
2
kHz
3
kHz
4
kHz
6
kHz
8
kHz
12
kHz
16
kHz
kW hp
2
kHz
3
kHz
4
kHz
6
kHz
8
kHz
12
kHz
16
kHz
200 V
03200050 1.1 1.5 93 95 99 104 113 122 0.75 1.0 78 80 84 87 94 101
03200066 1.5 2.0 100 102 107 113 122 133 1.1 1.5 89 91 94 99 108 116
03200080 2.2
3.0
123 126 133 139 147 135 1.5 2.0 97 99 105 109 114 106
03200106 3.0 136 141 149 158 149 138 2.2 3.0 115 118 120 115 108 102
04200137 4.0 5.0 3.0 3.0
04200185 5.5 7.5 4.0 5.0
06200330 11 15 394 413 452 490 483
7.5 10 277 290 316 342 394
06200440 15 20 463 484 528 531 483 11 15 366 382 417 424 393
400 V
03400025 1.1 1.5 80 84 94 103 123 141 0.75 1.0 79 76 83 92 108 124
03400031 1.5 2.0 88 92 104 115 137 160 1.1 1.5 69 73 82 91 107 124
03400045 2.2 3.0 104 112 125 139 167 182 1.5 2.0 83 88 99 109 131 142
03400062 3.0
5.0
114 122 137 153 166 171 2.2 3.0 98 105 118 131 131 141
03400078 4.0 145 158 180 173 164 166 3.0 5.0 115 125 135 131 134 135
03400100 5.0 7.5 160 177 172 168 167 166 4.0 5.0 134 131 129 131 134 135
04400150
04400172
06400350 18.5 25 417 456 532 613 679
15 25 389 424 498 532 559
06400420 22 30 515 561 657 670 679 18.5 30 455 497 520 523 551
06400470 30 40 656 677 657 665 681 22 30 511 516 520 525 551
575 V
06500100 7.5 10 215 239 287 334 5.5 7.5 187 208 249 291
06500150 11 15 284 315 376 438 7.5 10 265 294 351 410
06500190 15 20 362 399 484 568 11 15 317 350 418 496
06500230 18.5 25 448 505 596 682 15 20 382 421 508 523
06500290 22 30 18.5 25
06500350 30 40 22 30