2.10.1 XTE alarm
The XTE alarm tells you when your ship goes off course by more than the limit set
(XTE alarm boundaries).
1. Turn on [XTE Alarm] in the [Alarm] menu.
2. Tap [XTE Alarm Value] to display the software keyboard.
3. Set the value, then tap .
4. Tap the close button to finish.
2.10.2 Depth alarm
The depth alarm tells you when the depth to the bottom is shallower than the value
you set. Requires depth data.
1. Turn on [Depth Alarm] in the [Alarm] menu.
2. Tap [Depth Alarm Value] to display the software keyboard.
3. Set the value, then tap .
4. Tap the close button to finish.
2.10.3 SST alarm
The sea surface temperature alarms tells you when the sea surface temperature is
over, under, within, or out of range of the temperature you set. Requires a temperature
sensor.
1. Tap [Sea Surface Temperature Alarm] on the [Alarm] menu.
2. Tap [Over], [Under], [Within], [Out of] or [Shear]. Follow the appropriate procedure
below.
Alarm
setting
Go to point
Intended
course
:Alarm area
Starting point

Table of Contents

Other manuals for Furuno TZTL12F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno TZTL12F and is the answer not in the manual?

Furuno TZTL12F Specifications

General IconGeneral
BrandFuruno
ModelTZTL12F
CategoryMonitor
LanguageEnglish

Related product manuals