GE Multilin T60 Transformer Protection System H-3
APPENDIX H H.1 CHANGE NOTES
H
Table H–3: MAJOR UPDATES FOR T60 MANUAL REVISION Z1
PAGE
(Y3)
PAGE
(Z1)
CHANGE DESCRIPTION
--- --- Add Added CPU options U and V to order code tables in chapter 2, a note above Rear Terminal View
figure in chapter 3, and CPU Module Communications Wiring figure in chapter 3
--- --- Add Added Parallel Redundancy Protocol (PRP) to order code tables and specifications in chapter 2,
section 5.2.5d Settings > Product Setup > Communications > Network, section 6.3.1 Actual
Values > Status > PRP, and Appendix B Modbus table and F627 and F628 enumeration tables
-- -- Add Added CT failure feature to Table 2-2 Other Device Functions, to chapter 5 Settings > Control
Elements > Monitoring Elements > CT Failure Detector, and Appendix B table F124 List of
Elements as bitmask element 246 CT Failure
1-1 1-1 Add Added General Cautions and Warnings to section 1.1.1
1-5 1-5 Update Revised section 1.3.1 on system requirements, including addition of support for Windows 7 and
Windows Server 2008
2-12 2-12 Update Updated several specifications
5-25 5-25 Add Added section 5.2.5e Routing
5-103 5-103 Update Updated Figures 5-28 and 5-29 Dual Breaker Control Scheme Logic, sheets 1 and 2
5-107 5-107 Update Updated Figure 5-30 Disconnect Switch Scheme Logic
5-282 5-282 Add Reinserted section 5.8.5c Remote Devices: ID of Device for Receiving GSSE/GOOSE Messages,
meaning the Settings > Input/Outputs > Remote Devices settings
Table H–4: MAJOR UPDATES FOR T60 MANUAL REVISION Y3
PAGE
(Y2)
PAGE
(Y3)
CHANGE DESCRIPTION
-- xi Add Added battery disposal information as chapter 0
5-90 5-90 Add Added a reference to the T35/T60 Reference Winding Selection and CT Ratio Mismatch
Application Note in section 5.4.4b General Transformer Settings, specifically the Reference
Winding setting
Table H–5: MAJOR UPDATES FOR T60 MANUAL REVISION Y2
PAGE
(Y1)
PAGE
(Y2)
CHANGE DESCRIPTION
All All Update Minor changes throughout document
All All Delete Deleted CPU options U and V
1-1 1-1 Update Updated Figure 1-1 Rear Nameplate
3-8 3-8 Update Updated Figure 3-10 Rear Terminal View
Table H–6: MAJOR UPDATES FOR T60 MANUAL REVISION Y1 (Sheet 1 of 3)
PAGE
(X2)
PAGE
(Y1)
CHANGE DESCRIPTION
All All Delete Deleted content pertaining to Ethernet switch
Title Title Update Changed part numbers. Updated address and contact information.
1-1 1-1 Update Updated address and contact information
2- 2- Add Added CPU options T, U, and V to order code table
2- 2- Delete Removed E, G, H, J, S from CPU options from order code tables
2-10 2-10 Delete Deleted 9S, 2S, 2T from replacement module order code Tables 2-7 and 2-8
2-12 2-12 Update Changed number of phase distance and ground distance zones to 5 in Protection Elements
section 2.2.1
2-21 2-21 Update Updated Ethernet fiber table in section 2.2.8 Communications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE T60 and is the answer not in the manual?

GE T60 Specifications

General IconGeneral
Frequency50/60 Hz
MountingPanel Mount
Protection FunctionsOvercurrent
Communication ProtocolsDNP3
Operating Temperature+70°C
EnclosureIP54 (front panel)